Relay Boards

12- Relay Board



We are instrumental in offering Twelve Relay Board. It is the simplest way to activate anything remotely. Easiest way to send the signal to remote location. Remote can be integrated with different signal generating point - Control panel, Micro-controller, Joy Stick etc. The relay operating mode can be momentary, toggle, latching, delayed action. Remote is small and light weight. Another bigger remote also can be provided for industrial use. 


Specifications: 

  • Power Supply 12 V DC for both remote (generally battery operated) and relay board
  • Wireless Relay Board-12
  • Operates on 12 V DC– 2-pin connector (white) provided on board
  • Operation Mode Selector: A set of six pin jumpers are proved with marking M (momentary), T (toggle) and L (latch). They stand for: M : momentary : Relay will be ON till the button is pressed, T : toggle : the relay will be ON when a button is pressed, it will be OFF when button is pressed again, L : latch : Only one relay will be ON at a time, when another button is pressed relay corresponding to that button will be ON , all other relays will be OFF
  • Shorting first two pins from left makes operation M (momentary), Shorting middle two pins will make operation T ( toggling), Shorting last two pins will make operation L (latching)


4- Relay Board


We offer our customers an excellent quality range of Four Relay Board. It is the simplest way to activate anything remotely (motor, alarm, display). These are are widely used and made as per requirements of our valued clients.

Specifications:

Power Supply 12 V DC for both remote (generally battery operated) and relay board
Wireless Relay Board- 4
Same as Wireless Relay Board-12 except mode selection feature
Operating mode selection for individual relay
There are four “U” pins one for each relay.When pin shorts central pin and pin marked “U” – the operation is controlled by micro-controller. When it shorts central pin to pin marked “D”, the operation is controlled by decoder– It can be momentary or latching depending on decoder
With micro controller relays will operate in Toggle mode. If “T” pins are shorted it will being Latching mode. If “M” pins are shorted it will be in Momentary mode